Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	40
Date	08/07/14
Start Time	16:24:40
Diameter Midpoint
 11.3	1.26102e+006
 11.8	1.05794e+006
 12.2	938210
 12.6	885478
 13.1	825856
 13.6	769007
 14.1	702221
 14.6	638941
 15.1	574290
 15.7	512943
 16.3	446872
 16.8	385032
 17.5	328212
 18.1	271477
 18.8	214523
 19.5	163215
 20.2	121711
 20.9	87321.2
 21.7	59813
 22.5	39693.4
 23.3	24417.7
 24.1	15137.8
 25.0	8637.88
 25.9	5021.23
 26.9	2848.12
 27.9	1476.76
 28.9	898.432
 30.0	503.582
 31.1	332.594
 32.2	205.563
 33.4	174.319
 34.6	126.656
 35.9	134.75
 37.2	126.069
 38.5	117.192
 40.0	112.381
 41.4	123.626
 42.9	77.4824
 44.5	21.9454
 46.1	0
 47.8	0
 49.6	0
 51.4	0
 53.3	0
 55.2	0
 57.3	0
 59.4	0
 61.5	0
 63.8	275.085
 66.1	636.532
 68.5	1336.53
 71.0	1886.51
 73.7	2475.03
 76.4	2879.08
 79.1	3281.78
 82.0	3565.15
 85.1	3490.39
 88.2	3250.17
 91.4	2995.13
 94.7	2602.3
 98.2	2279.81
101.8	1824.94
105.5	1434.57
109.4	1146.31
113.4	845.163
117.6	701.559
121.9	491.427
126.3	420.882
131.0	288.371
135.8	188.938
140.7	138.055
145.9	123.769
151.2	81.5142
156.8	61.9811
162.5	72.5347
168.5	56.4156
174.7	62.413
181.1	38.0901
187.7	56.4371
194.6	49.4147
201.7	30.1594
209.1	29.7745
216.7	31.0579
224.7	36.8041
232.9	34.1516
241.4	20.0033
250.3	26.8629
259.5	14.2829
269.0	21.6052
278.8	12.6421
289.0	7.5435
299.6	4.01808
310.6	9.30138
322.0	9.86315
333.8	13.9252
346.0	7.8741
358.7	20.0419
371.8	2.19614
385.4	2.23588
399.5	2.26271
414.2	2.30517
429.4	2.34936
445.1	0
461.4	4.85337
478.3	4.95215
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.6629
High Voltage	9943.64
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	13.4793
Mean(nm)	14.4184
Geo. Mean(nm)	14.0153
Mode(nm)	11.3419
Geo. Std. Dev.	1.22601
Total Concentration(#/cm)	1.03837e+007
Comment	